LIFT2TY - cable with 2 steel wires

[tidy error]

LIFT2TY - cable with 2 steel wires

[tidy error]

Use

The cable is particularly suitable as a managing and control cable within elevator and crane installations. The two outer lying steel supporting elements can be removed without damaging the outer sheath. The cable provides great flexibility at low temperatures due to the high quality of the materials used

Construction

Conductor:

CU threads cl.6

Isolation:

PVC

Conductor colour:

Black with white numbering

Construction:

The conductors are stored in concentric layers

Outer sheath:

PVC, black

The outer sheath is also supplied with

2 isolated steel wires in which the cable

can be hung.

Technical data

Rated voltage:

300/500 V

Test voltage:

2000 V

Temperature flexible:

-30° to + 70°

Temperature fixed:

-40° to + 70°

Standards

IEC 332-3/A
IEC 227
      Item number Number / cross sections mm² Packing Outer diameter approx. mm Number of meters
  12367 310905007 5x0,75 Drum 10,9x28,9 meters
  5922 310906010 6x1 Drum 10,9/23,5 meters
  5923 310908010 8x1 Drum 12,7/27,9 meters
  5924 310912010 12x1 Drum 12,9/27,3 meters